0835 cross-linkable semi-conductive shielding compound is used as strippable insulation shield for cross-linked polyethylene insulation power cable rated voltage up to 35KV. It's suitable for high temperature vulcanization processing method. 0835 provides excellence processability, fine surface smoothness, stable volume resistivity, low pre-cure or scorch characteristic, lower stripping force with anti-tearing property, leaving clean surface for insulation after stripped.3, Technical Parameter
Property | Test Method | Unit | Value |
Density at 23°C | ASTM D 1505 | g/ cm3 | ≤ 1.13 |
Tensile Strength (200 mm/min) Tensile Strength Retention (Heat Aging at 135°C after 168h) |
ASTM D 638 | MPA % |
≥ 13 85 |
Elongation at Break before ageing Elongation Retention (Heat Aging at 135°C after 168h) |
ASTM D 638 | % % |
280 85 |
Volume Resistivity at 20°C Volume Resistivity at 90°C |
ASTM-D991 | W.cm W.cm |
60 ≤ 600 |
Hot Set Test Conditions At 200 ±2 °C x 0.2 MPa for 15 min |
IEC 540-14 | ||
Elongation after loading Permanent Deformation |
% % |
≤ 60 ≤ 2 |
|
Moisture Content | KARL FISCHER | ppm | ≤ 500 |
Brittleness Temperature | ASTM-D746 | -40°C | |
Stripping Force | Q/TNYM 1-2012 | N/cm | 15 |
Zone | Zone 1 | Zone 2 | Zone 3 | Zone 4 | Flange | Tube | Screw |
Temperature Range°C | 80-85 | 90-95 | 100-105 | 105-110 | 105 | 105 | 50-55 |
4,Storage: