Product Description:
1. Product Name: Closed water cooling system
Closed cooling tower is full-closed, it will not appear the phenomenon such as the dust into the cooling pipe and
control system to lead the pipeline blockage.
Closed cooling tower adopts soft water circulating system, it is not easy to form the incrustation to lead the pipeline
overheating. It adopts automatic digital control system, there're other features, such as: energy saving,
environmental protection, high efficiency, high accuracy and easy to use. Full-confined space, the cooling medium is
not affected by the outside environment, and the environment will not be polluted.
It can cool brine, oil, alcohol, quenching and chemical liquid and other mediums, the composition will not be affected
the medium is no-loss, and no leakage. Closed cooling tower adopts the type which is air cooling, evaporation heat,
double cooling, and the cooling efficiency is higher and energy saving. The type is prying, so the installation of
pipeline is simple and convenient. You don't need dig the reservoir, it can save water and protect environment.
Basic introduction of closed cooling tower FBH-250T:
Compact structure, can be placed in the plant; Applicable standard temperature drop cooling items (5 ºC temperature drop)
Operating principle:
1. Internal circulation: the circulating water enters the surface cooler after being heated by heat exchange of the heat source, and the heat is sent to the outside through the surface cooler. The cooled circulating water is then sent to the heat source by the water pump.
2. External circulation: the spray water is sent to the spray system from the water tank. After the water is sprayed, it contacts the surface cooler for heat exchange. Part of the hot steam is discharged through the fan. The cooled spray water falls into the water tank and then circulates again.
Features of closed cooling tower FBH-250T:
1. Compact structure: compared with the cross flow type, the countercurrent tower has a more compact product structure, more coil cooling area arrangement, and is more suitable for cooling projects with smaller temperature difference.
2. Overall system: because the cooling tower occupies a small area on the ground, combined with the circulating water pump, it can be made into an integrated machine, which is convenient to move.
3. Scope of use: As the tower body is compact and can be placed in the workshop, medium frequency power supply cooling and mechanical water jacket cooling are applicable; It is especially applicable to projects with small temperature difference, such as the cooling of water source heat pump units.
Advantages of closed cooling tower FBH-250T:
1. Stability: Closed cooling tower circulating water is usually soft water closed circuit circulation, effectively preventing equipment damage caused by scale generated in the tower or user equipment during long-term use.
2. Water saving: Compared with the traditional cooling tower, the closed cooling tower is more suitable for use in areas where water resources are scarce because of its fully closed internal circulation and efficient dehydration device.
3. Energy saving: The closed cooling tower can control the number of fans to start according to the temperature, and the opening and closing of the spray pump, or it can install a regulating valve to control the flow.
4. Environmental protection: the closed cooling tower will not be polluted through the fully closed internal circulating water and can be used continuously. The relative evaporation of spray water is less, which maximizes the protection of the environment.
5. Longer service life: Our factory uses high-quality metal materials to greatly improve the image ability. The service and maintenance time limit is usually more than 10 years, and the later maintenance and cost are low.
Technical Specifications:
Model |
Cooling capacity |
Motor power |
Fan delivery |
Spray pump |
Pipe diameter of device interface |
|
Flow |
Heat extraction |
|
|
Water pump power |
Water inlet/outlet |
Overflow |
Sewage draining exit |
Water replenishing |
power |
|
m³/h |
KW |
KW |
m³/h |
KW |
mm |
mm |
mm |
mm |
30D |
30 |
174 |
1.5*2 |
38400 |
0.75 |
DN80 |
DN25 |
DN25 |
DN25 |
40D |
40 |
232 |
1.5*2 |
51200 |
1.1 |
DN100 |
DN32 |
DN32 |
DN32 |
50D |
50 |
290 |
1.5*2 |
64000 |
1.5 |
DN100 |
DN32 |
DN32 |
DN32 |
65D |
65 |
378 |
2.2*2 |
83200 |
1.5 |
DN100 |
DN32 |
DN32 |
DN32 |
80D |
80 |
465 |
3*2 |
102400 |
2.2 |
DN125 |
DN40 |
DN40 |
DN40 |
100D |
100 |
581 |
4*2 |
128000 |
3 |
DN125 |
DN40 |
DN40 |
DN40 |
125D |
125 |
727 |
5.5*2 |
160000 |
3 |
DN150 |
DN40 |
DN40 |
DN40 |
150D |
150 |
872 |
4*3 |
192000 |
4 |
DN150 |
DN40 |
DN40 |
DN40 |
180D |
180 |
1046 |
5.5*3 |
240000 |
4 |
DN125*2 |
DN40 |
DN40 |
DN40 |
200D |
200 |
1163 |
4 *4 |
256000 |
4 |
DN125*2 |
DN40 |
DN40 |
DN40 |
225D |
225 |
1308 |
4 *4 |
256000 |
5.5 |
DN150*2 |
DN40 |
DN40 |
DN40 |
250D |
250 |
1453 |
5*4 |
320000 |
5.5 |
DN150*2 |
DN40 |
DN40 |
DN40 |
Company Profile: